GENERAL ORDERING INFORMATION:
Specify Meter Color & Digit Size, Meter Power and a Signal Conditioner from the list below. Specify Analog Output, Setpoint Output and Digital Interface if needed. These meters are shipped with a standard configuration and range shown below for each signal conditioner and output option type. All information for making changes is covered in the supplied Owners Manual. For other scalings or configurations, add the SC (Special Configuration) option.
You must be logged in to post a review.
Micro Series DC voltage and current panel meters with a DC signal conditioner board combine high accuracy with high read rate and a wide range of isolated output options for computer interface and control. Accuracy is 99.99% of full scale ±1 count.
Used as a direct-reading DC voltmeter, the Micro DC meter provides a full-scale readout of ±20,000 counts and five full-scale voltage ranges from 200.00 mV with 10 mV resolution to 660.0 V with 100 mV resolution. The 200.00 mV and 2.000 V ranges provide a high input impedance of 1 Gohm so as to minimize the load on the voltage signal. The maximum voltage which can be applied on the 20, 200 and 660 Vdc ranges is 660 Vac.
Used as a DC ammeter, the Micro DC meter provides a full-scale readout of ±20,000 counts and four full-scale direct-reading current ranges from 2.0000 mA with 0.1 mA resolution to 5.000 A with 1 mA resolution. The 5.000 A range measures the IR drop across a built-in 10 mW current shunt.
The Micro DC meter can be used with external current shunts, which typically produce 50 mV or 100 mV at their rated maximum current. Scaling from millivolts to amperes for a specific shunt value is easily accomplished from the front panel of the meter. The scalable readout is five full digits up to ±99,999 counts. Since the voltage signal from a current shunt can be noisy, the meter provides a selectable, adaptive moving-average digital filter, as explained below.
All voltage and current ranges are calibrated at the factory, with calibration factors for each range stored in an internal EEPROM. This allows ranges to be changed without recalibrating the meter.
All Micro DC voltmeters use Concurrent Slope (US Pat 5,262,780) analog-to-digital conversion, which allows up to 60 or 50 conversions per second while integrating the signal over a full power cycle. High read rate is ideal for peak capture, real-time computer interface, and control.
The peak value of the input signal is automatically captured and may be displayed via a front panel pushbutton command or a control signal at the rear connector since the last meter reset. Other controls at the rear connector include meter hold, meter reset, and decimal point selection.
The displayed readings and the data outputs can be separately selected to be either unfiltered or filtered.
5, 10 and 24 Vdc isolated excitation outputs are standard to power external devices, such as transducers or transmitters. In many cases, these outputs can eliminate the need for an external supply.
Plug-in isolated analog output, dual setpoint controller, and RS232/485 serial communications boards can upgrade Micro and Mighty Series meters from a simple monitor to system interface and control.
Micro Series meters can be powered from 95-240 Vac ±10% and 95-370 Vdc, or optionally from 12-34 Vac and 10-48 Vdc. Any setup functions and front panel keys may be locked out for simplified usage and security. The popular 1/8 DIN version with 0.56″ high digits is environmentally sealed to NEMA-4X (IP65) from the front when panel mounted, and is available with red or green LEDs.
DC Voltage Range | Resolution | Input Ohms | Error at 25°C ±1 count |
200.00 mV | 10 µV | 1 G | 0.01% FS |
2.000 V | 100 µV | 1 G | 0.01% FS |
20.000 V | 1 mV | 1 M | 0.01% FS |
200.00 V | 10 mV | 1 M | 0.01% FS |
660.0 V | 100 mV | 1 M | 0.03% FS |
DC Voltage Range | Resolution | Input Ohms | Error at 25°C ±1 count |
2.0000 mA | 0.1 µA | 100 | 0.01% FS |
20.000 mA | 1.0 µA | 10 | 0.01% FS |
200.00 mA | 10 µA | 1 | 0.01% FS |
5.000 A | 1.0 mA | 0.01 | 0.04% FS |
Display | |
Readout | 5 digits, 7-segment |
Digit Height | Available with 0.56", 1.0", 4.0" or 5.0" digits. |
Color | High brightness red. Green available with 0.56" digits. |
Range | -99999 to +99999 |
-99990 to +99990 (selectable count by 10 with rounding) | |
Indicators | Minus sign, 2 red LED lamps |
A-to-D Conversion | |
Technique | Concurrent Slope™ (Pat 5,262,780) |
A-to-D Rate | 60/s at 60 Hz, 50/s at 50 Hz |
Output Update | 56/s at 60 Hz, 47/s at 50 Hz |
Display Update | 3.5/s at 60 Hz, 3/s at 50 Hz |
Accuracy | |
Span Tempco | 0.003% of reading/°C |
Zero Tempco | 0.1 counts/°C |
Noise Rejection | |
CMR, DC to 60 Hz | 130 dB |
NMR at 50/60 Hz | 90 dB with min filtering |
Maximum Signal | |
Max applied voltage | 660 Vac for 20, 200 and 600 V ranges, 125 Vac for other ranges |
Current protection | 25x for 2 mA, 8x for 20 mA, 2.5x for 200 mA, 1x for 5 A |
Power | |
Voltage, std. | 95-240 Vac ±10% and 95-370 Vdc |
Voltage, opt. | 12-34 Vac and 10-48 Vdc |
Frequency | DC or 49-440 Hz |
Power isolation | Safety-rated to 250 Vac, meter ground to earth ground, |
DC to 60 Hz, 4.2 kVp per High Voltage Test |
Excitation Output | |
5 Vdc | 5 Vdc ±5%, 100 mA max |
10 Vdc | 10 Vdc ±5%, 120 mA max |
24 Vdc | 24 Vdc ±5%, 50 mA max |
Output isolation | 50 Vdc to meter ground |
Connector Pin Assignments |
![]() |
Environmental | |
Operating Temp. | 0°C to 60°C |
Storage Temp. | -40°C to 85°C |
Relative Humidity | 95% at 40°C, non-condensing |
Protection | NEMA-4X (IP-65) when panel mounted |
© 2022 Electro-Numerics. All Rights Reserved. Privacy Policy. Website by Mathis Consulting LLC | Developed by Cebu Web Maker